Viewable by the world

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 131 Next »

Location: 20 Lewis Hall, University of California, Berkeley

                                          Contact:  Tel: (510)-643-0914

Catalysis Laboratory Manager: Cooper Citek PhD ([email protected])


For ID card access to the Catalysis Laboratory in Lewis 20, please send the following information to the Manager:


Name as it appears on your Cal 1 card (Berkeley ID)
Berkeley email address
The ID number on the front of the Cal 1 card
The first six digits of the number on the back (bottom) of the Cal 1 card


Please check the status and reservation calendars below to reserve instrument time.


Instrument

Agilent

7890-5977A GC-MS

Waters Prep HPLC-MS

Autopurification System

Perkin Elmer

Axion 2 TOF MS

Bruker Vertex80

ATR-FT-IR

with MCT Detector

Shimadzu UV-2600i

UV-Vis

with Unisoku Cryostat-Stirrer

Shimadzu

Axima Performance

MALDI-TOF

Micromeritics

3Flex

Biotage Endeavor

High Pressure

Reactor

Mettler Toledo

ReactIR Probe

with EasyMax Thermostat

Viscotek

GPC

Jasco J-815

CD Spectropolarimeter

CH 650E Electrochemistry

Potentiostat

in Inert Atmosphere 

CEM Discover SP

Microwave Reactor

Biologic µSFM Stopped-Flow

UV-Vis-Fluorescence

Spectrometer

MBraun

Glovebox

Status

(tick)


(tick)

(tick)

(tick)(tick)(error)

(tick)  *Contact Superusers

(tick)

(tick)

(error)

*recalibrate before use

(tick)(tick)(tick)(tick)

(tick)

CalendarGCMSLCMSTOF MSFTIRUV-VisMALDI-TOF

3 Flex

Endeavor Pressure ReactorReactIRGPCCD




SOP and Manual Documents

AxION 2 TOF Maintenance Guide

SOP

Chemical Inventory

Download OPUS Viewer from Bruker

SOP

SOP

CO SOP

Chemical Inventory

SOP

SOP


Superuser Contacts

Magan Powell (Rittle)

magan_powell


Nicodemo Ciccia (Hartwig)

nciccia

Sarah Chen (Rittle)

sarah_chen


Chang Liu (Rittle)

chang-liu

Mathew See (Tilley)

mssee


John Brunn (Hartwig)

jbrunn


Alireza Pourghaderi (Maboudian)

alirezapourghaderi


Stuart McElhany (Maboudian)

stuartm

Alex Wheeler (Tilley)

talexander_wheeler

Tent Tangpradabkul (Schepartz)

tent.tangpradabkul


Kurtis Mickel Carsch  (Long)

kcarsch


Jesse Peltier (Long)

jlpeltier


Rachel Rohde (Long)

rachel_rohde

Jeremy Nicolai (Hartwig)

jeremy.nicolai



Andre Sanchez (Maimone)

andre_sanchez_243


Alex Wheeler (Tilley)

talexander_wheeler

Nicodemo Ciccia (Hartwig)

nciccia


Jake Shi (Hartwig)

jake_shi

Isaac Joyner (Hartwig)

ijoyner

Christina Pierson (Hartwig)

christina_pierson


Isaac Yu (Hartwig)

isaacyu


Please contact Catalysis Center Manager for permission to use.

Please contact Catalysis Center Manager for permission to use.




 Schedule

     


Schedule

Ion source: ESI and APCI

Columns available: Reverse phase C18 columns (both analytical and prep),

                                   Reverse phase C8 column (prep),

                                   HILIC columns (both analytical and prep).

Schedule

       Ion Source: ESI and APCI

       For HRMS, error < 5ppm

       UPLC for fast LC analysis: 18000psi

       Columns available: reverse phase C18 column

                                      Cogent Diamond Hydride column

Schedule

     Optical resolution: <0.2 cm-1

     Time resolution: Rapid Scan: 110 spec/sec; Step Scan: 10 ns.

Snowhouse Solutions, Science Instruments - Products - Atomic Force  Microscope, Battery Cycler, Potentiostat, Stopped-Flow, Mini Spectrometer,  Infrared Spectrometer, Raman Spectrometer, Scientific Cameras, Bench-Top  Lasers, Radiation MeasurementsSchedule

    The stopped-flow unit is also adapted to the FTIR spectrometer for IR kinetics.



Agilent 7890B-5977A GC-MS system     Schedule



Malvern Viscotek GPC system           Schedule

Mobile phase: THF

Molecular weight range: 1,000 – 200,000

Schedule

  8 parallel reaction vails, 2 reaction gases, up to 500 psi, 200 °C



ReactIR15 and EasyMax ChemSynthesis Station


CD Spectrometer