Instrument | Agilent 7890-5977A GC-MS | Waters Prep HPLC-MS Autopurification System | Perkin Elmer Axion 2 TOF HR-MS | Bruker Vertex80 ATR-FT-IR with MCT Detector | Shimadzu UV-2600i UV-Vis with Unisoku Cryostat-Stirrer | Shimadzu Axima Performance MALDI-TOF | Micromeritics 3Flex | Biotage Endeavor High Pressure Reactor | Mettler Toledo ReactIR Probe with EasyMax Thermostat | Jasco J-815 CD Spectropolarimeter | CH 650E Electrochemistry Potentiostat in Inert Atmosphere | CEM Discover SP Microwave Reactor | Biologic µSFM Stopped-Flow UV-Vis Spectrometer | MBraun Glovebox |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
*Contact Superusers | ||||||||||||||
Calendar | GCMS | LCMS | TOF MS | FTIR | UV-Vis | MALDI-TOF | Endeavor Pressure Reactor | ReactIR | CD | |||||
SOP and Manual Documents | SOP | |||||||||||||
Superuser Contacts | Magan Powell (Rittle) Nicodemo Ciccia (Hartwig) | Sarah Chen (Rittle) Chang Liu (Rittle) | Mathew See (Tilley) John Brunn (Hartwig) | Alireza Pourghaderi (Maboudian) Stuart McElhany (Maboudian) | Alex Wheeler (Tilley) | Tent Tangpradabkul (Schepartz) | Kurtis Mickel Carsch (Long) Jesse Peltier (Long)
| Jeremy Nicolai (Hartwig) | Andre Sanchez (Maimone) Alex Wheeler (Tilley) | Isaac Joyner (Hartwig) | Christina Pierson (Hartwig) Isaac Yu (Hartwig) | Please contact Catalysis Center Manager for permission to use. | Please contact Catalysis Center Manager for permission to use. |
Schedule
Schedule
Ion source: ESI and APCI
Columns available: Reverse phase C18 columns (both analytical and prep),
Reverse phase C8 column (prep),
HILIC columns (both analytical and prep).
Schedule
Ion Source: ESI and APCI
For HRMS, error < 5ppm
UPLC for fast LC analysis: 18000psi
Columns available: reverse phase C18 column
Cogent Diamond Hydride column
Schedule
Optical resolution: <0.2 cm-1
Time resolution: Rapid Scan: 110 spec/sec; Step Scan: 10 ns.
Schedule
The stopped-flow unit is also adapted to the FTIR spectrometer for IR kinetics.
Agilent 7890B-5977A GC-MS system Schedule
Malvern Viscotek GPC system Schedule
Mobile phase: THF
Molecular weight range: 1,000 – 200,000
Schedule
8 parallel reaction vails, 2 reaction gases, up to 500 psi, 200 °C
ReactIR15 and EasyMax ChemSynthesis Station
CD Spectrometer